ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
MSCONS D.16B

MSCONS — EDIFACT Metered Services Consumption Report Message (D.16B)

The MSCONS message conveys metered consumption reports (electricity, gas, water, heat) between energy-market participants: meter readings, consumption periods, hourly or quarter-hour profiles, energy qualities. It is the daily backbone of exchanges between suppliers, network operators and balance-responsible parties in the European market. This page summarises the segment structure as published by UN/CEFACT for directory D.16B.

Purpose

The MSCONS message conveys metered consumption reports (electricity, gas, water, heat) between energy-market participants: meter readings, consumption periods, hourly or quarter-hour profiles, energy qualities. It is the daily backbone of exchanges between suppliers, network operators and balance-responsible parties in the European market.

This page focuses on the structure published by UN/CEFACT for directory D.16B. The segments listed, their status (M / C), position and repetition factor are extracted from the official file mscons_c.htm hosted on service.unece.org.

Segment structure

The MSCONS D.16B message has 15 header entries, 27 detail entries and 2 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
00010UNHMessage headerM1
00020BGMBeginning of messageM1
00030DTMDate/time/periodM×9
00040CUXCurrenciesC×9
00050  SG1Group (×9)C×9
00060  RFFReferenceM1
00070  DTMDate/time/periodC×9
00080    SG2Group (×99)C×99
00090    NADName and addressM1
00100      SG3Group (×9)C×9
00110      RFFReferenceM1
00120      DTMDate/time/periodC×9
00130        SG4Group (×9)C×9
00140        CTAContact informationM1
00150        COMCommunication contactC×9

Detail

Pos.TagNameSRep.
00160UNSSection controlM1
00170  SG5Group (×99999)M×99999
00180  NADName and addressM1
00190    SG6Group (×99999)M×99999
00200    LOCPlace/location identificationM1
00210    DTMDate/time/periodC×9
00220      SG7Group (×99)C×99
00230      RFFReferenceM1
00240      DTMDate/time/periodC×9
00250        SG8Group (×99)C×99
00260        CCICharacteristic/class idM1
00270        DTMDate/time/periodC×99
00280          SG9Group (×99999)C×99999
00290          LINLine itemM1
00300          PIAAdditional product idC×9
00310          IMDItem descriptionC×9
00320          PRIPrice detailsC×9
00330          NADName and addressC×9
00340          MOAMonetary amountC×9
00350            SG10Group (×9999)M×9999
00360            QTYQuantityM1
00370            DTMDate/time/periodC×9
00380            STSStatusC×9
00390              SG11Group (×99)C×99
00400              CCICharacteristic/class idM1
00410              MEAMeasurementsC×99
00420              DTMDate/time/periodC×9

Summary

Pos.TagNameSRep.
00430CNTControl totalC×99
00440UNTMessage trailerM1

Changes vs D.96A

The MSCONS message is not published in directory D.96A. No "D.96A → D.16B" comparison line can therefore be produced — see the block below for details.

This message is not published in directory D.96A: it was introduced into the standard after that release and therefore has no historical baseline for comparison. The first directory indexed on ediverse.io sets the reference; later changes are then documented from one release to the next in subsequent directories.

Structural example

Minimal example of an MSCONS D.16B message with mandatory segments only. The goal is to show the exact version declared in UNH (MSCONS:D:16B:UN) — not to replicate a full business case.

edifact mscons-d16b-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL016001'
UNH+1+MSCONS:D:16B:UN'
BGM+7+MSCONS-2026-W19+9'
DTM+137:202605140800:203'
DTM+163:202605140000:203'
DTM+164:202605142400:203'
RFF+ACW:DELIVERY-PT-FR1234ABCD'
NAD+MS+5410000000123::9'
NAD+MR+5410000000456::9'
LOC+172+FR-DSO-PT-1234ABCD::293'
LIN+1++1-1?:1.8.0:SRW'
QTY+220:18540:KWH'
DTM+163:202605140000:203'
DTM+164:202605142400:203'
UNT+14+1'
UNZ+1+CTRL016001'

Common errors

  • Misaligned UNH tokens — The UNH+...+MSCONS:D:16B:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.16B, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: MSCONS D.10A, MSCONS D.21B, MSCONS D.24A.

X12 functional equivalent: X12 867.

← All EDIFACT versions