MSCONS D.10A

MSCONS — EDIFACT Metered Services Consumption Report Message (D.10A)

The MSCONS message conveys metered consumption reports (electricity, gas, water, heat) between energy-market participants: meter readings, consumption periods, hourly or quarter-hour profiles, energy qualities. It is the daily backbone of exchanges between suppliers, network operators and balance-responsible parties in the European market. This page summarises the segment structure as published by UN/CEFACT for directory D.10A.

Purpose

The MSCONS message conveys metered consumption reports (electricity, gas, water, heat) between energy-market participants: meter readings, consumption periods, hourly or quarter-hour profiles, energy qualities. It is the daily backbone of exchanges between suppliers, network operators and balance-responsible parties in the European market.

This page focuses on the structure published by UN/CEFACT for directory D.10A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file mscons_c.htm hosted on service.unece.org.

Segment structure

The MSCONS D.10A message has 15 header entries, 27 detail entries and 2 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodM×9
0040CUXCurrenciesC×9
0050  SG1Group (×9)C×9
0060  RFFReferenceM1
0070  DTMDate/time/periodC×9
0080    SG2Group (×99)C×99
0090    NADName and addressM1
0100      SG3Group (×9)C×9
0110      RFFReferenceM1
0120      DTMDate/time/periodC×9
0130        SG4Group (×9)C×9
0140        CTAContact informationM1
0150        COMCommunication contactC×9

Detail

Pos.TagNameSRep.
0160UNSSection controlM1
0170  SG5Group (×99999)M×99999
0180  NADName and addressM1
0190    SG6Group (×99999)M×99999
0200    LOCPlace/location identificationM1
0210    DTMDate/time/periodC×9
0220      SG7Group (×99)C×99
0230      RFFReferenceM1
0240      DTMDate/time/periodC×9
0250        SG8Group (×99)C×99
0260        CCICharacteristic/class idM1
0270        DTMDate/time/periodC×99
0280          SG9Group (×99999)C×99999
0290          LINLine itemM1
0300          PIAAdditional product idC×9
0310          IMDItem descriptionC×9
0320          PRIPrice detailsC×9
0330          NADName and addressC×9
0340          MOAMonetary amountC×9
0350            SG10Group (×9999)M×9999
0360            QTYQuantityM1
0370            DTMDate/time/periodC×9
0380            STSStatusC×9
0390              SG11Group (×99)C×99
0400              CCICharacteristic/class idM1
0410              MEAMeasurementsC×99
0420              DTMDate/time/periodC×9

Summary

Pos.TagNameSRep.
0430CNTControl totalC×99
0440UNTMessage trailerM1

Changes vs D.96A

The MSCONS message is not published in directory D.96A. No "D.96A → D.10A" comparison line can therefore be produced — see the block below for details.

This message is not published in directory D.96A: it was introduced into the standard after that release and therefore has no historical baseline for comparison. The first directory indexed on ediverse.io sets the reference; later changes are then documented from one release to the next in subsequent directories.

Structural example

Minimal example of an MSCONS D.10A message with mandatory segments only. The goal is to show the exact version declared in UNH (MSCONS:D:10A:UN) — not to replicate a full business case.

edifact mscons-d10a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL010001'
UNH+1+MSCONS:D:10A:UN'
BGM+7+MSCONS-2026-W19+9'
DTM+137:202605140800:203'
DTM+163:202605140000:203'
DTM+164:202605142400:203'
RFF+ACW:DELIVERY-PT-FR1234ABCD'
NAD+MS+5410000000123::9'
NAD+MR+5410000000456::9'
LOC+172+FR-DSO-PT-1234ABCD::293'
LIN+1++1-1?:1.8.0:SRW'
QTY+220:18540:KWH'
DTM+163:202605140000:203'
DTM+164:202605142400:203'
UNT+14+1'
UNZ+1+CTRL010001'

Common errors

  • Misaligned UNH tokens — The UNH+...+MSCONS:D:10A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.10A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: MSCONS D.16B, MSCONS D.21B, MSCONS D.24A.

X12 functional equivalent: X12 867.

← All EDIFACT versions