ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
INSDES D.99B

INSDES — EDIFACT Instruction to Despatch Message (D.99B)

The INSDES message is the despatch instruction sent to a warehouse or logistics site by a principal: it indicates what to pick, pack and ship, to which destination, with which carrier, and under which logistics terms. This page summarises the segment structure as published by UN/CEFACT for directory D.99B.

Purpose

The INSDES message is the despatch instruction sent to a warehouse or logistics site by a principal: it indicates what to pick, pack and ship, to which destination, with which carrier, and under which logistics terms.

This page focuses on the structure published by UN/CEFACT for directory D.99B. The segments listed, their status (M / C), position and repetition factor are extracted from the official file insdes_c.htm hosted on service.unece.org.

Segment structure

The INSDES D.99B message has 34 header entries, 22 detail entries and 4 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodM×9
0040INPParties and instructionC×99
0050FTXFree textC×9
0060  SG1Group (×9)C×9
0070  RFFReferenceM1
0080  DTMDate/time/periodC×9
0090    SG2Group (×9)C×9
0100    NADName and addressM1
0110    LOCPlace/location identificationC×9
0120      SG3Group (×9)C×9
0130      RFFReferenceM1
0140      DTMDate/time/periodC×9
0150        SG4Group (×9)C×9
0160        CTAContact informationM1
0170        COMCommunication contactC×9
0180          SG5Group (×9)C×9
0190          TODTerms of delivery or transportM1
0200          LOCPlace/location identificationC×9
0210          FTXFree textC×9
0220            SG6Group (×9)C×9
0230            TDTDetails of transportM1
0240            PCDPercentage detailsC1
0250              SG7Group (×9)C×9
0260              LOCPlace/location identificationM1
0270              DTMDate/time/periodC×9
0280                SG8Group (×9)C×9
0290                EQDEquipment detailsM1
0300                MEAMeasurementsC×9
0310                EQAAttached equipmentC×9
0320                  SG9Group (×9)C×9
0330                  HANHandling instructionsM1
0340                  FTXFree textC×9

Detail

Pos.TagNameSRep.
0350  SG10Group (×9999)C×9999
0360  LINLine itemM1
0370  PIAAdditional product idC×9
0380  IMDItem descriptionC×99
0390  QTYQuantityC×9
0400  GINGoods identity numberC×99
0410  INPParties and instructionC×99
0420  DTMDate/time/periodC×9
0430  FTXFree textC×9
0440  MOAMonetary amountC×99
0450  ALIAdditional informationC×99
0460    SG11Group (×9)C×9
0470    RFFReferenceM1
0480    DTMDate/time/periodC1
0490      SG12Group (×99)C×99
0500      NADName and addressM1
0510      QTYQuantityC1
0520      DTMDate/time/periodC1
0530      LOCPlace/location identificationC×99
0540        SG13Group (×9999)C×9999
0550        PCIPackage identificationM1
0560        GINGoods identity numberC×9

Summary

Pos.TagNameSRep.
0570UNSSection controlM1
0580MOAMonetary amountC×99
0590CNTControl totalC×9
0600UNTMessage trailerM1

Changes vs D.96A

The INSDES message is not published in directory D.96A. No "D.96A → D.99B" comparison line can therefore be produced — see the block below for details.

This message is not published in directory D.96A: it was introduced into the standard after that release and therefore has no historical baseline for comparison. The first directory indexed on ediverse.io sets the reference; later changes are then documented from one release to the next in subsequent directories.

Structural example

Minimal example of an INSDES D.99B message with mandatory segments only. The goal is to show the exact version declared in UNH (INSDES:D:99B:UN) — not to replicate a full business case.

edifact insdes-d99b-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL099001'
UNH+1+INSDES:D:99B:UN'
BGM+271+INSDES-2026-0408+9'
DTM+137:20260514:102'
DTM+2:20260517:102'
NAD+OB+5410000000123::9'
NAD+SH+5410000000456::9'
NAD+CN+5410000000789::9'
LIN+1++3520000001234:EN'
QTY+21:10'
UNT+10+1'
UNZ+1+CTRL099001'

Common errors

  • Misaligned UNH tokens — The UNH+...+INSDES:D:99B:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.99B, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: INSDES D.01B, INSDES D.10A, INSDES D.16B, INSDES D.21B, INSDES D.24A, INSDES D.00B, INSDES D.02B, INSDES D.05A, INSDES D.08A, INSDES D.13B, INSDES D.18B, INSDES D.20B.

X12 functional equivalent: X12 940.

← All EDIFACT versions