ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
COSTOR D.96A

COSTOR — EDIFACT Container Stuffing / Stripping Order Message (D.96A)

The COSTOR message is the order sent by a forwarder or shipper to a container depot or consolidator to stuff (load) or strip (unload) goods into/from an LCL container: it specifies the goods, target container, booking and B/L references, and the handling constraints. Confirmation is returned via COSTCO. This page summarises the segment structure as published by UN/CEFACT for directory D.96A.

Purpose

The COSTOR message is the order sent by a forwarder or shipper to a container depot or consolidator to stuff (load) or strip (unload) goods into/from an LCL container: it specifies the goods, target container, booking and B/L references, and the handling constraints. Confirmation is returned via COSTCO.

This page focuses on the structure published by UN/CEFACT for directory D.96A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file costor_s.htm hosted on service.unece.org.

Segment structure

The COSTOR D.96A message has 51 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030FTXFree textC×9
0040RFFReferenceC×9
0050  SG1Group (×1)M1
0060  TDTDetails of transportM1
0070  LOCPlace/location identificationC×9
0080  DTMDate/time/periodC×9
0090    SG2Group (×9)M×9
0100    NADName and addressM1
0110    CTAContact informationC×9
0120      SG3Group (×999)M×999
0130      EQDEquipment detailsM1
0140      RFFReferenceC×9
0150      EQNNumber of unitsC1
0160      DTMDate/time/periodC×9
0170      TSRTransport service requirementsC×9
0180      LOCPlace/location identificationC×9
0190      DIMDimensionsC×9
0200        SG4Group (×9)C×9
0210        NADName and addressM1
0220        DTMDate/time/periodC×9
0230          SG5Group (×999)M×999
0240          CNIConsignment informationM1
0250          RFFReferenceC×9
0260          NADName and addressC×9
0270            SG6Group (×999)C×999
0280            GIDGoods item detailsM1
0290            HANHandling instructionsC×9
0300            TMPTemperatureC×9
0310            RNGRange detailsC×9
0320            FTXFree textC×9
0330            DTMDate/time/periodC×9
0340              SG7Group (×9)C×9
0350              NADName and addressM1
0360              DTMDate/time/periodC×9
0370              MEAMeasurementsC×9
0380              PCIPackage identificationC×9
0390              DOCDocument/message detailsC×9
0400                SG8Group (×999)C×999
0410                SGPSplit goods placementM1
0420                MEAMeasurementsC×9
0430                  SG9Group (×9)C×9
0440                  DGSDangerous goodsM1
0450                  FTXFree textC×9
0460                  MEAMeasurementsC×9
0470                    SG10Group (×999)C×999
0480                    SGPSplit goods placementM1
0490                    MEAMeasurementsC×9
0500                    CNTControl totalM1
0510UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

This page documents directory D.96A itself: it serves as the reference for every other version of the message. The synthesis below describes the structural changes that later directories will introduce relative to it.

No top-level differences detected between D.96A and D.96A for this message. Differences are then limited to nested groups and code lists.

Structural example

Minimal example of an COSTOR D.96A message with mandatory segments only. The goal is to show the exact version declared in UNH (COSTOR:D:96A:UN) — not to replicate a full business case.

edifact costor-d96a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL096001'
UNH+1+COSTOR:D:96A:UN'
BGM+266+COSTOR-2026-STUFF-0007+9'
DTM+137:20260514:102'
DTM+200:20260518:102'
TDT+20+TRUCK-FR1234+3'
LOC+11+FRLEH::6'
NAD+CA+5410000000123::9'
NAD+CN+5410000000456::9'
EQD+CN+MSCU1234567+45G1+++5'
GID+1+18:CT'
UNT+10+1'
UNZ+1+CTRL096001'

Common errors

  • Misaligned UNH tokens — The UNH+...+COSTOR:D:96A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.96A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: COSTOR D.10A, COSTOR D.16B, COSTOR D.21B, COSTOR D.24A.

← All EDIFACT versions