CONITT D.96A

CONITT — EDIFACT Invitation to Tender Message (D.96A)

The CONITT message conveys the invitation to tender sent by a buyer — public or private — to potential suppliers: subject of the consultation, lots, selection criteria, schedule, general terms and contractual clauses. It sets the stage for the subsequent CONTEN (response) and CONDPV (award). This page summarises the segment structure as published by UN/CEFACT for directory D.96A.

Purpose

The CONITT message conveys the invitation to tender sent by a buyer — public or private — to potential suppliers: subject of the consultation, lots, selection criteria, schedule, general terms and contractual clauses. It sets the stage for the subsequent CONTEN (response) and CONDPV (award).

This page focuses on the structure published by UN/CEFACT for directory D.96A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file conitt_s.htm hosted on service.unece.org.

Segment structure

The CONITT D.96A message has 87 header entries, 50 detail entries and 2 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030RFFReferenceM1
0040DTMDate/time/periodM1
0050AUTAuthentication resultC×2
0060AGRAgreement identificationC×2
0070  SG1Group (×1000)C×1000
0080  INDIndex detailsM1
0090  RCSRequirements and conditionsM1
0100    SG2Group (×1)M1
0110    GISGeneral indicatorM1
0120      SG3Group (×1)M1
0130      BIIStructure identificationM1
0140      IMDItem descriptionM×9
0150        SG4Group (×1000)C×1000
0160        BIIStructure identificationM1
0170        RCSRequirements and conditionsM1
0180        GISGeneral indicatorM×10
0190        NADName and addressC1
0200        LOCPlace/location identificationC1
0210        APRAdditional price informationC1
0220        ALIAdditional informationC×2
0230        QTYQuantityC×5
0240        DTMDate/time/periodC×10
0250        RTERate detailsC×9
0260          SG5Group (×10)C×10
0270          RFFReferenceM1
0280          DTMDate/time/periodC×2
0290          GISGeneral indicatorC×5
0300          FTXFree textC×5
0310            SG6Group (×5)C×5
0320            CUXCurrenciesM1
0330            DTMDate/time/periodC×5
0340            FTXFree textC1
0350              SG7Group (×2)C×2
0360              ALCAllowance or chargeM1
0370              RFFReferenceC1
0380              DTMDate/time/periodC1
0390              RNGRange detailsC1
0400              FTXFree textC×10
0410                SG8Group (×20)C×20
0420                PCDPercentage detailsM1
0430                RFFReferenceC1
0440                  SG9Group (×100)C×100
0450                  RCSRequirements and conditionsM1
0460                  BIIStructure identificationM1
0470                  FTXFree textC×9
0480                    SG10Group (×100)M×100
0490                    ARDAmounts relationship detailsM1
0500                    MOAMonetary amountM×6
0510                    FTXFree textC×10
0520                      SG11Group (×5)C×5
0530                      TAXDuty/tax/fee detailsM1
0540                      MOAMonetary amountC1
0550                      LOCPlace/location identificationC×5
0560                        SG12Group (×15)C×15
0570                        ALCAllowance or chargeM1
0580                        ALIAdditional informationC×5
0590                          SG13Group (×1)C1
0600                          QTYQuantityM1
0610                          RNGRange detailsC1
0620                            SG14Group (×1)C1
0630                            PCDPercentage detailsM1
0640                            RNGRange detailsC1
0650                              SG15Group (×1)C1
0660                              MOAMonetary amountM1
0670                              RNGRange detailsC1
0680                                SG16Group (×1)C1
0690                                RTERate detailsM1
0700                                RNGRange detailsC1
0710                                  SG17Group (×5)C×5
0720                                  TAXDuty/tax/fee detailsM1
0730                                  MOAMonetary amountC1
0740                                    SG18Group (×20)C×20
0750                                    NADName and addressM1
0760                                    LOCPlace/location identificationC×25
0770                                    FIIFinancial institution informationC×9
0780                                    FTXFree textC×5
0790                                      SG19Group (×5)C×5
0800                                      RFFReferenceM1
0810                                      DTMDate/time/periodC×5
0820                                        SG20Group (×5)C×5
0830                                        DOCDocument/message detailsM1
0840                                        DTMDate/time/periodC×5
0850                                          SG21Group (×5)C×5
0860                                          CTAContact informationM1
0870                                          COMCommunication contactC×5

Detail

Pos.TagNameSRep.
0880UNSSection controlM1
0890  SG22Group (×1000)M×1000
0900  BIIStructure identificationM1
0910  RCSRequirements and conditionsM1
0920  GISGeneral indicatorM×10
0930    SG23Group (×10)C×10
0940    RFFReferenceM1
0950    DTMDate/time/periodC1
0960      SG24Group (×100)C×100
0970      DIMDimensionsM1
0980      APRAdditional price informationC1
0990      FTXFree textC1
1000        SG25Group (×100)C×100
1010        LINLine itemM1
1020          SG26Group (×1000)C×1000
1030          IMDItem descriptionM1
1040          RFFReferenceC×5
1050          GISGeneral indicatorC×5
1060            SG27Group (×1000)M×1000
1070            QTYQuantityM1
1080            GISGeneral indicatorC×3
1090            APRAdditional price informationC1
1100              SG28Group (×3)C×3
1110              PRIPrice detailsM1
1120              GISGeneral indicatorM×3
1130                SG29Group (×2)C×2
1140                ARDAmounts relationship detailsM1
1150                MOAMonetary amountC1
1160                  SG30Group (×5)C×5
1170                  TAXDuty/tax/fee detailsM1
1180                  MOAMonetary amountC1
1190                  LOCPlace/location identificationC×5
1200                    SG31Group (×5)C×5
1210                    RCSRequirements and conditionsM1
1220                    BIIStructure identificationM1
1230                    GISGeneral indicatorM1
1240                      SG32Group (×2)C×2
1250                      ALCAllowance or chargeM1
1260                      RFFReferenceC1
1270                      DTMDate/time/periodC1
1280                      RNGRange detailsC1
1290                      FTXFree textC×10
1300                        SG33Group (×20)C×20
1310                        PCDPercentage detailsM1
1320                        RFFReferenceC1
1330                          SG34Group (×9)C×9
1340                          IMDItem descriptionM1
1350                          QTYQuantityC1
1360                          MOAMonetary amountC1
1370                          PRIPrice detailsC1

Summary

Pos.TagNameSRep.
1380CNTControl totalC×10
1390UNTMessage trailerM1

Changes vs D.96A

This page documents directory D.96A itself: it serves as the reference for every other version of the message. The synthesis below describes the structural changes that later directories will introduce relative to it.

No top-level differences detected between D.96A and D.96A for this message. Differences are then limited to nested groups and code lists.

Structural example

Minimal example of an CONITT D.96A message with mandatory segments only. The goal is to show the exact version declared in UNH (CONITT:D:96A:UN) — not to replicate a full business case.

edifact conitt-d96a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL096001'
UNH+1+CONITT:D:96A:UN'
BGM+710+CONITT-2026-0017+9'
RFF+AGA:TENDER-2026-0017'
DTM+137:20260514:102'
DTM+38:20260615:102'
NAD+BY+5410000000123::9'
NAD+SE+5410000000456::9'
LIN+1++3520000001234:EN'
IMD+F++:::Server rack 42U, redundant PSU, 19 inch'
QTY+21:48'
UNT+11+1'
UNZ+1+CTRL096001'

Common errors

  • Misaligned UNH tokens — The UNH+...+CONITT:D:96A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.96A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: CONITT D.01B, CONITT D.10A, CONITT D.16B, CONITT D.21B, CONITT D.24A, CONITT D.97A, CONITT D.99B, CONITT D.00B, CONITT D.02B, CONITT D.05A, CONITT D.08A, CONITT D.13B, CONITT D.18B, CONITT D.20B.

X12 functional equivalent: X12 840.