ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
MOVINS D.02B

MOVINS — EDIFACT Stowage Instruction Message (D.02B)

The MOVINS message conveys container loading and discharge instructions sent by a carrier to a port terminal: which containers to load, discharge or re-stow on which vessel, at which position and under which constraints. This page summarises the segment structure as published by UN/CEFACT for directory D.02B.

Purpose

The MOVINS message conveys container loading and discharge instructions sent by a carrier to a port terminal: which containers to load, discharge or re-stow on which vessel, at which position and under which constraints.

This page focuses on the structure published by UN/CEFACT for directory D.02B. The segments listed, their status (M / C), position and repetition factor are extracted from the official file movins_c.htm hosted on service.unece.org.

Segment structure

The MOVINS D.02B message has 45 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodM1
0040  SG1Group (×9)C×9
0050  RFFReferenceM1
0060  DTMDate/time/periodC×9
0070    SG2Group (×9)C×9
0080    NADName and addressM1
0090      SG3Group (×9)C×9
0100      CTAContact informationM1
0110      COMCommunication contactC×9
0120        SG4Group (×3)M×3
0130        TDTTransport informationM1
0140        LOCPlace/location identificationM1
0150        DTMDate/time/periodM×99
0160        RFFReferenceC1
0170        FTXFree textC1
0180          SG5Group (×9999)M×9999
0190          HANHandling instructionsM1
0200            SG6Group (×9999)M×9999
0210            LOCPlace/location identificationM1
0220            RFFReferenceM×99
0230            FTXFree textC×9
0240            MEAMeasurementsC×9
0250            DIMDimensionsC×9
0260            LOCPlace/location identificationC×9
0270            NADName and addressM×99
0280              SG7Group (×1)C1
0290              TMPTemperatureM1
0300              RNGRange detailsC1
0310                SG8Group (×99)C×99
0320                EQDEquipment detailsM1
0330                EQNNumber of unitsC1
0340                  SG9Group (×99)C×99
0350                  EQAAttached equipmentM1
0360                  EQNNumber of unitsC1
0370                    SG10Group (×9999)C×9999
0380                    GIDGoods item detailsM1
0390                    GDSNature of cargoC1
0400                      SG11Group (×999)C×999
0410                      RFFReferenceM1
0420                        SG12Group (×99)M×99
0430                        DGSDangerous goodsM1
0440                        FTXFree textC1
0450UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

Top-level differences between D.96A and D.02B for the MOVINS message (segments directly inside header / detail / summary, ignoring nested groups). The comparison is indicative: a given tag may have evolved inside nested groups without showing up in this synthesis.

Segments added vs D.96A

  • CTA in the header section (status M, repeat ×1) — not present at the top of the corresponding D.96A section.
  • COM in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.

Status changes (M ↔ C)

  • NAD (header): status C in D.96A → M in D.02B.

Max-repeat changes

  • NAD (header): repeat ×3 in D.96A → ×1 in D.02B.

Structural example

Minimal example of an MOVINS D.02B message with mandatory segments only. The goal is to show the exact version declared in UNH (MOVINS:D:02B:UN) — not to replicate a full business case (see the MOVINS D.96A page for an annotated example).

edifact movins-d02b-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL002001'
UNH+1+MOVINS:D:02B:UN'
BGM+244+MOVINS-2026-0188+9'
DTM+137:202605141430:203'
TDT+20+MSC1234W+1++MSC::ZZZ+++9301234:103:::MSC OSCAR'
LOC+11+FRLEH::6'
LOC+13+NLRTM::6'
EQD+CN+MSCU1234567+45G1+++5'
HAN+L'
LOC+147+0010186::ZZZ'
UNT+9+1'
UNZ+1+CTRL002001'

Common errors

  • Misaligned UNH tokens — The UNH+...+MOVINS:D:02B:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.02B, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: MOVINS D.96A, MOVINS D.01B, MOVINS D.10A, MOVINS D.16B, MOVINS D.21B, MOVINS D.24A, MOVINS D.97A, MOVINS D.99B, MOVINS D.00B, MOVINS D.05A, MOVINS D.08A, MOVINS D.13B, MOVINS D.18B, MOVINS D.20B.

← All EDIFACT versions