ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
IFTSTA D.05A

IFTSTA — EDIFACT Multimodal Transport Status Message (D.05A)

The IFTSTA message conveys multimodal-shipment statuses from a carrier or 3PL to the trade parties: key events (departure, arrival, hub, customs), geolocation and exceptions. This page summarises the segment structure as published by UN/CEFACT for directory D.05A.

Purpose

The IFTSTA message conveys multimodal-shipment statuses from a carrier or 3PL to the trade parties: key events (departure, arrival, hub, customs), geolocation and exceptions.

This page focuses on the structure published by UN/CEFACT for directory D.05A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file iftsta_c.htm hosted on service.unece.org.

Segment structure

The IFTSTA D.05A message has 78 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodC×9
0040TSRTransport service requirementsC1
0050  SG1Group (×9)C×9
0060  NADName and addressM1
0070    SG2Group (×9)C×9
0080    CTAContact informationM1
0090    COMCommunication contactC×9
0100      SG3Group (×9)C×9
0110      RFFReferenceM1
0120      DTMDate/time/periodC1
0130      LOCPlace/location identificationC×9
0140      FTXFree textC×9
0150      CNTControl totalC×9
0160        SG4Group (×99999)C×99999
0170        CNIConsignment informationM1
0180        LOCPlace/location identificationC×9
0190        CNTControl totalC×9
0200          SG5Group (×99)M×99
0210          STSStatusM1
0220          RFFReferenceC×999
0230          DTMDate/time/periodC×9
0240          DOCDocument/message detailsC1
0250          FTXFree textC×9
0260            SG6Group (×9)C×9
0270            NADName and addressM1
0280              SG7Group (×9)C×9
0290              CTAContact informationM1
0300              COMCommunication contactC×9
0310              LOCPlace/location identificationC1
0320              PCIPackage identificationC×99
0330                SG8Group (×99)C×99
0340                TDTTransport informationM1
0350                DTMDate/time/periodC×9
0360                RFFReferenceC×9
0370                  SG9Group (×9)C×9
0380                  LOCPlace/location identificationM1
0390                  DTMDate/time/periodC×9
0400                    SG10Group (×99)C×99
0410                    EQDEquipment detailsM1
0420                    MEAMeasurementsC×9
0430                    DIMDimensionsC×9
0440                    SELSeal numberC×9
0450                    RFFReferenceC×9
0460                    TPLTransport placementC×9
0470                    TMDTransport movement detailsC1
0480                      SG11Group (×9)C×9
0490                      LOCPlace/location identificationM1
0500                      DTMDate/time/periodC×9
0510                        SG12Group (×99)C×99
0520                        EQAAttached equipmentM1
0530                        SELSeal numberC×9
0540                          SG13Group (×9)C×9
0550                          LOCPlace/location identificationM1
0560                          DTMDate/time/periodC×9
0570                            SG14Group (×99)C×99
0580                            GIDGoods item detailsM1
0590                            HANHandling instructionsC×9
0600                            SGPSplit goods placementC×99
0610                            DGSDangerous goodsC×9
0620                            FTXFree textC×9
0630                            GDSNature of cargoC×9
0640                            LOCPlace/location identificationC×9
0650                            QTYQuantityC×9
0660                              SG15Group (×99)C×99
0670                              MEAMeasurementsM1
0680                              EQNNumber of unitsC1
0690                                SG16Group (×99)C×99
0700                                DIMDimensionsM1
0710                                EQNNumber of unitsC1
0720                                  SG17Group (×99)C×99
0730                                  PCIPackage identificationM1
0740                                  GINGoods identity numberC×9999
0750                                    SG18Group (×9)C×9
0760                                    RFFReferenceM1
0770                                    DTMDate/time/periodC×9
0780UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

Top-level differences between D.96A and D.05A for the IFTSTA message (segments directly inside header / detail / summary, ignoring nested groups). The comparison is indicative: a given tag may have evolved inside nested groups without showing up in this synthesis.

Segments added vs D.96A

  • TPL in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.
  • TMD in the header section (status C, repeat ×1) — not present at the top of the corresponding D.96A section.
  • SGP in the header section (status C, repeat ×99) — not present at the top of the corresponding D.96A section.
  • DGS in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.
  • GDS in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.
  • QTY in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.

Max-repeat changes

  • GIN (header): repeat ×9 in D.96A → ×9999 in D.05A.

Structural example

Minimal example of an IFTSTA D.05A message with mandatory segments only. The goal is to show the exact version declared in UNH (IFTSTA:D:05A:UN) — not to replicate a full business case (see the IFTSTA D.96A page for an annotated example).

edifact iftsta-d05a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL005001'
UNH+1+IFTSTA:D:05A:UN'
BGM+77+STA-2026-1042+9'
DTM+137:202605141430:203'
NAD+CA+5410000000123::9'
CNI+1'
STS+1++1'
RFF+CN:CMR-9981'
DTM+334:202605141000:203'
LOC+175+FRPAR::6'
UNT+10+1'
UNZ+1+CTRL005001'

Common errors

  • Misaligned UNH tokens — The UNH+...+IFTSTA:D:05A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.05A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: IFTSTA D.96A, IFTSTA D.01B, IFTSTA D.10A, IFTSTA D.16B, IFTSTA D.21B, IFTSTA D.24A, IFTSTA D.97A, IFTSTA D.99B, IFTSTA D.00B, IFTSTA D.02B, IFTSTA D.08A, IFTSTA D.13B, IFTSTA D.18B, IFTSTA D.20B.

X12 functional equivalent: X12 214.

← All EDIFACT versions