ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
COSTCO D.24A

COSTCO — EDIFACT Container Stuffing Confirmation Message (D.24A)

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L. This page summarises the segment structure as published by UN/CEFACT for directory D.24A.

Purpose

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L.

This page focuses on the structure published by UN/CEFACT for directory D.24A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file costco_c.htm hosted on service.unece.org.

Segment structure

The COSTCO D.24A message has 70 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
00010UNHMessage headerM1
00020BGMBeginning of messageM1
00030DTMDate/time/periodC×9
00040FTXFree textC×9
00050  SG1Group (×9)C×9
00060  RFFReferenceM1
00070  DTMDate/time/periodC×9
00080    SG2Group (×1)M1
00090    TDTTransport informationM1
00100    DTMDate/time/periodC×9
00110    RFFReferenceC×9
00120      SG3Group (×9)C×9
00130      LOCPlace/location identificationM1
00140      DTMDate/time/periodC×9
00150        SG4Group (×9)M×9
00160        NADName and addressM1
00170          SG5Group (×9)C×9
00180          CTAContact informationM1
00190          COMCommunication contactC×9
00200            SG6Group (×99999)M×99999
00210            EQDEquipment detailsM1
00220            RFFReferenceC×9
00230            DTMDate/time/periodC×9
00240            TSRTransport service requirementsC×9
00250            DIMDimensionsC×9
00260            SELSeal numberC×9
00270            EQAAttached equipmentC×9
00280            HANHandling instructionsC×99
00290            ATTAttributeC×99
00300            NADName and addressC×9
00310              SG7Group (×999)C×999
00320              DGSDangerous goodsM1
00330              ATTAttributeC×9
00340              FTXFree textC×9
00350              MEAMeasurementsC×9
00360                SG8Group (×9)C×9
00370                CTAContact informationM1
00380                COMCommunication contactC×9
00390                  SG9Group (×9)C×9
00400                  TMPTemperatureM1
00410                  RNGRange detailsC1
00420                    SG10Group (×99999)M×99999
00430                    CNIConsignment informationM1
00440                    RFFReferenceC×9
00450                      SG11Group (×99999)C×99999
00460                      GIDGoods item detailsM1
00470                      HANHandling instructionsC×9
00480                        SG12Group (×9)C×9
00490                        TMPTemperatureM1
00500                        RNGRange detailsC1
00510                        FTXFree textC×9
00520                        MEAMeasurementsC×9
00530                        PCIPackage identificationC×9
00540                        DOCDocument/message detailsC×9
00550                          SG13Group (×999)M×999
00560                          SGPSplit goods placementM1
00570                          MEAMeasurementsC×9
00580                            SG14Group (×999)C×999
00590                            DGSDangerous goodsM1
00600                            ATTAttributeC×9
00610                            FTXFree textC×9
00620                            MEAMeasurementsC×9
00630                              SG15Group (×9)C×9
00640                              CTAContact informationM1
00650                              COMCommunication contactC×9
00660                                SG16Group (×999)C×999
00670                                SGPSplit goods placementM1
00680                                MEAMeasurementsC×9
00690                                CNTControl totalC1
00700UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

Top-level differences between D.96A and D.24A for the COSTCO message (segments directly inside header / detail / summary, ignoring nested groups). The comparison is indicative: a given tag may have evolved inside nested groups without showing up in this synthesis.

Segments added vs D.96A

  • COM in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.
  • ATT in the header section (status C, repeat ×99) — not present at the top of the corresponding D.96A section.

Status changes (M ↔ C)

  • LOC (header): status C in D.96A → M in D.24A.
  • CTA (header): status C in D.96A → M in D.24A.
  • TMP (header): status C in D.96A → M in D.24A.
  • CNT (header): status M in D.96A → C in D.24A.

Max-repeat changes

  • RFF (header): repeat ×9 in D.96A → ×1 in D.24A.
  • LOC (header): repeat ×9 in D.96A → ×1 in D.24A.
  • CTA (header): repeat ×9 in D.96A → ×1 in D.24A.
  • HAN (header): repeat ×9 in D.96A → ×99 in D.24A.
  • TMP (header): repeat ×9 in D.96A → ×1 in D.24A.
  • RNG (header): repeat ×9 in D.96A → ×1 in D.24A.

Structural example

Minimal example of an COSTCO D.24A message with mandatory segments only. The goal is to show the exact version declared in UNH (COSTCO:D:24A:UN) — not to replicate a full business case (see the COSTCO D.96A page for an annotated example).

edifact costco-d24a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL024001'
UNH+1+COSTCO:D:24A:UN'
BGM+267+COSTCO-2026-0152+9'
DTM+137:202605141430:203'
DTM+138:202605141200:203'
FTX+AAI+++Stuffing completed - high cube container - 24 pallets'
UNT+6+1'
UNZ+1+CTRL024001'

Common errors

  • Misaligned UNH tokens — The UNH+...+COSTCO:D:24A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.24A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: COSTCO D.96A, COSTCO D.10A, COSTCO D.16B, COSTCO D.21B.

← All EDIFACT versions